ACCURATE TRAJECTORY TRACKING CONTROL OF WATER HYDRAULIC CYLINDER WITH NON-IDEAL ON/OFF VALVES

Matti Linjama, Kari T. Koskinen and Matti Vilenius

Institute of Hydraulics and Automation, Tampere University of Technology, P.O. BOX 589, FIN-33101, Tampere, Finland
matti.linjama@tut.fi


Abstract

The aim of the work is to develop an on/off valve based trajectory tracking control solution without fast and/or continuous switching of valves. The pulse code modulation method is used to realise stepwise control of inflow and outflow of the actuator. Both inflow and outflow paths have five parallel-connected two-way solenoid valves, each having different flow capacity according to binary series, and a four-way on/off valve is used for changing direction of movement. Cost function based open-loop and closed-loop control solutions are developed and it is demonstrated how the cost function weights can be used to find a reasonable trade-off between tracking performance and pressure surges. Closed-loop results show accurate and reasonably smooth position tracking and simultaneous pressure level control. Achieved control performance is close to that of water hydraulic servo systems.

Keywords: Pulse Code Modulation, On/Off Control, Tracking Control



 

BACK



©2003 Fluid Power Net All rights reserved. Disclaimer